CODA無創(chuàng)血壓系統(tǒng)為美國Kent公司產(chǎn)品,CODA多通道無創(chuàng)血壓系統(tǒng)設(shè)計上考慮兩個方面,一是無創(chuàng)血壓測量,另一個是高通量測量。CODA多通道系統(tǒng)是每一款能同時自動測量48個實驗動物的系統(tǒng)。
CODATM無創(chuàng)血壓系統(tǒng)為美國Kent公司產(chǎn)品,CODATM多通道無創(chuàng)血壓系統(tǒng)設(shè)計上考慮兩個方面,一是無創(chuàng)血壓測量,另一個是高通量測量。CODATM多通道系統(tǒng)是每一款能同時自動測量48個實驗動物的系統(tǒng)。
產(chǎn)品特色:
真正的多通道同步檢測,支持2到48只動物高通道測量動物血壓
專利技術(shù)體積壓力法測量,市面上唯一直接測量大小鼠舒張產(chǎn)品經(jīng)驗證與直接的血壓測量方法,數(shù)據(jù)上有100%的相關(guān)性
實驗條件溫和,鼠尾26度以上可檢測數(shù)據(jù)
可檢測收縮壓,舒張壓,平均壓,心率,鼠尾血流量,血容量等多參數(shù)
全自動實驗過程,無需人工干預(yù),分析報告直出
CODATM多通道無創(chuàng)血壓系統(tǒng)應(yīng)用了體積壓力傳感器技術(shù)(VPR)。VPR方法是已經(jīng)經(jīng)過科學應(yīng)用證明了的,與遙測法,直接血壓測量法具有100%相關(guān)性的實驗方法。全球市場上,CODATM系列無創(chuàng)血儀系統(tǒng)是基于VPR技術(shù),直接測定動物的舒張壓的產(chǎn)品。而其它公
司的產(chǎn)品,由于不具備這項技術(shù),其舒張壓均為計算得出。
我們的配套軟件,使操作者可以實時的不間斷的觀測實驗數(shù)據(jù)。從實驗數(shù)據(jù)中獲取和輸出血壓參數(shù)非常的簡單和容易。軟件自帶數(shù)據(jù)的分析、統(tǒng)計功能,可直接輸出實驗結(jié)果報告。這項功能在保證有效數(shù)據(jù)的前提下,還極大的減少了操作者的工作量,提高了工作
效率。另外軟件數(shù)據(jù)兼容Excel等電子表格軟件,可輸出到第三方軟件進行統(tǒng)計,分析。
System Includes
NIBP controller
Database software
Far infrared warming platform(s)
Animal holder, one for each channel (*size to be defined at time of order)
VPR sensor and occlusion cuff kit, one for each channel (*size to be defined at time of order)
Cuff storage case(s)
Infrared thermometer
Product manual
1-Year 100% Parts & Labor Standard Warranty (Optional Premium Warranty available for purchase)
With the CODA®, You Can Measure
4 blood pressure parameters: systolic, diastolic, mean BP and heart rate
Mice as small as 8 grams to rats as large as 950 grams
Diastolic blood pressure measured, not just a calculated value
Dark-skinned mice (C57BL/6) without difficulty
Awake or anesthetized animals with equal accuracy, consistency, and reliability
Anesthetized animals in a radiological environment (MRI compatibility)
See How the Noninvasive Tail-Cuff System Works
The animal nose cone holders that accompany the CODA system were specifically designed for noninvasive tail blood pressure measurements. The clear acrylic holders provide unrestricted breathing and allow complete visibility to the researcher.
The VPR sensor incorporates a specially designed differential pressure transducer that measures the systolic and diastolic blood pressure by determining the blood volume in the tail. We have cuff sizes for mice as small as 8 grams to rats as large as 950 grams.
About Volume Pressure Recording (VPR)
VPR is a clinically validated method to measure blood pressure in mice and rats by determining the tail blood volume using a volume pressure recording sensor and an occlusion tail-cuff. VPR provides 99% correlation with telemetry and direct blood pressure measurements. Only our VPR technology can actually measure the diastolic blood pressure; all other tail-cuff technologies estimate (calculate) the diastolic blood pressure in mice and rats.
Features & Benefits
Multifunctional Monitoring Capability
Measures systolic, diastolic, mean BP, heart rate, tail blood volume and blood flow
Extremely Accurate
Diastolic blood pressure is measured, not just calculated
For Mice and Rats
Measures mice and rats as small as 8 grams and as large as 950 grams
High Sensitivity
Measures dark-skinned mice (C57BL/6) without difficulty
Versatile Application
Measures awake or anesthetized animals with equal accuracy, consistency, and reliability
MRI Compatible
Able to measure anesthetized animals in a radiological environment
High Throughput Capability
Connect up to 6 high throughput controllers to measure up to 48 animals
電話 :
地址 :
電話 :
地址 :
電話 :
地址 :